Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Rev. bras. ortop ; 53(5): 564-569, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-977875

ABSTRACT

ABSTRACT Objective: The aim of the study was to compare the mechanical behavior of interference screw tibial fixation vs. screw-plus-staple tibial fixation in an animal model. Methods: Thirty-six pieces of swine knee specimens were selected and divided into two groups: Group 1, tibial fixation with interference screw (n = 17), and Group 2, fixation with interference screw and staple (n = 19). The models were submitted to a single cycle of tension testing. The following variables were measured: graft cross-sectional area, failure point on 10 mm (F10), yield load (Fy), and stiffness. Results: The mean values of graft cross-sectional area, F10, Fy, and stiffness did not present significant differences between the groups. Conclusion: The addition of a second staple-type ligament fixation device, complementing the interference screw, did not increase the mechanical safety of the system.


RESUMO Objetivo: Comparar o comportamento mecânico da fixação tibial com parafuso de interferência versus parafuso de interferência com agrafe, em modelo animal. Métodos: Foram selecionadas 36 peças de joelho suíno e divididas em dois grupos: Grupo 1, fixação tibial com parafuso de interferência (n = 17) e Grupo 2, fixação com parafuso de interferência e agrafe (n = 19). Os modelos foram submetidos a teste de ciclo único de tração. Foram mensuradas as seguintes variáveis: medida da área de seção transversal do enxerto, ponto de falha nos 10 mm (F10), yield load (Fy) e rigidez. Resultados: Os valores médios de área de seção transversal do enxerto, F10, Fy, e rigidez não apresentaram diferenças significativas entre os grupos. Conclusão: A adição de um segundo dispositivo de fixação ligamentar tibial tipo agrafe, complementar ao parafuso de interferência, não aumentou a segurança mecânica do sistema.


Subject(s)
Animals , Orthopedic Fixation Devices , Tendons , Tibia , Biomechanical Phenomena , Anterior Cruciate Ligament
2.
Arq. odontol ; 53: 1-7, jan.-dez. 2017. tab
Article in Portuguese | LILACS, BBO | ID: biblio-906069

ABSTRACT

Objetivo: O objetivo desse estudo foi avaliar e comparar as propriedades mecânicas dos cimentos resinosos duais convencionais e autoadesivos em macro e nanoescala. Métodos: Foram confeccionados 15 espécimes de cada marca de cimentos resinosos, AllCem (FGM), RelyX ARC (3M/ESPE) e RelyX U200 (3M/ESPE), para cada teste realizado (flexão de três pontos, compressão e nanoindentação) de acordo com as instruções dos fabricantes. Os espécimes foram fotoativados com aparelho Optilux Demetron (Kerr) por 40 segundos e armazenados em frascos escuros a 37ºC por 24 horas. Foram obtidos os resultados de resistência flexural, resistência à compressão, dureza e de módulo de Young para os diferentes testes mecânicos. Os dados foram avaliados pelos testes ANOVA, múltiplas comparações de Tukey HSD para análise dos valores de resistência, dureza e módulo de elasticidade entre os diferentes cimentos resinosos e ANOVA dois critérios e múltiplas comparações de Games Howell para análise dos módulos de Young entre os diferentes experimentos. Resultados: Os resultados revelaram que o AllCem obteve os maiores valores de resistência flexural e compressão axial (129±22,01 MPa; 243,71±29,75, respectivamente) e o RelyX U200 os menores valores (82,35±19,83 MPa; 134,57±48,93 MPa, respectivamente). Os valores de dureza não diferiram entre os cimentos estudados. No teste de flexão os valores de módulo de Young não diferiram entre os cimentos resinosos. No teste de compressão axial o AllCem apresentou módulo de Young estatisticamente maiores que dos demais cimentos. Para nanoindentação AllCem e RelyX U200 apresentaram maiores valores de módulo de Young que RelyX ARC. Os valores de módulo de Young diferiram significativamente entre todos os experimentos (p<0.05). Conclusão: Os valores das propriedades dos cimentos resinosos podem ser influenciados pelo tipo de experimento (macro- ou nanoescala) realizado.(AU)


Aim: The aim of this study was to evaluate and compare the mechanical properties of conventional and self-adhesive dual resin cements in macroscale and nanoscale. Methods: Fifteen specimens of each brand of resin cement ­ AllCem (FGM), RelyX ARC (3M/ ESPE), and RelyX U200 (3M/ESPE) ­ were made for each test performed in this study (three point bending, compression, and nanoindentation) according to the manufacturer's instructions. The specimens were photoactivated with Optilux Demetron (Kerr) for 40 seconds and stored in the dark at 37°C for 24 hours. Subsequently, they were submitted to flexural strength and axial compression tests at a speed of 1 mm/min, as well as to the Berkovich nanoindentation test. The results of flexural strength, compressive strength, hardness, and Young's modulus were obtained for the different mechanical tests. Data were evaluated by ANOVA tests; multiple comparisons of Tukey HSD to analyze the values of strength, hardness, and Young's modulus among the different resin cements; and ANOVA two criteria and multiple comparisons of Games Howell to analyze the Young's modulus within the different experiments. Results: The results showed that AllCem obtained the highest values of flexural strength and axial compression (129±22.01, 243.71±29.75 MPa, respectively), while RelyX U200 presented the lowest values (82.35 ± 19.83, 134.57 ± 48.93 MPa, respectively). The hardness values did not differ among the studied cements. In the flexural test, the Young's modulus values did not differ between the resin cements. In the axial compression test, AllCem presented a Young's modulus that was statistically higher than the other cements. In the nanoindentation test, AllCem and RelyX U200 presented higher values for Young's modulus than RelyX ARC. Young's modulus values differed significantly among all experiments (p <0.05). Conclusion: The values of resin cement properties can be influenced by the type of experiment (macroscale and nanoscale) performed.(AU)


Subject(s)
Compressive Strength , Dental Materials , Hardness Tests , Materials Science , Resin Cements/analysis , Torsion, Mechanical , Resins, Synthetic
3.
Full dent. sci ; 7(25): 64-69, jan.2016. tab
Article in Portuguese | LILACS | ID: lil-790080

ABSTRACT

O objetivo deste estudo foi avaliar a correlação entre as cores nomeadas com identificações iguais de dentes artificiais de resina acrílica de diferentes marcas comerciais. Foram selecionadas cinco marcas: Vipi Dent Plus (VIPI), Biolux OMC (VIPI), Biocler G II (Dentbrás), Natus Dent (Dentbrás) e Tritone (VIPI), todas utilizando o mesmo padrão de nomenclatura. De cada marca comercial foram utilizadas as cores: 60, 62, 65, 66, 67 e 69. Para realizar as comparações de cor foi utilizado o aparelho espectrofotômetro Vita Easy Shade. Após três medições de cada cor, foi obtida a média das leituras, todas realizadas no centro do dente, no mesmo horário e com fundo cinza claro padronizado. Assim, os valores de L*, a* e b* foram obtidos. Esses valores foram tabulados para cálculos do ∆E, onde ∆E< ou = 3 representa diferença de cor significativa e perceptível. Observou-se correlação entre as marcas comerciais na cor 60 Biocler GII e Natus Dent (ΔE= 3); Biocler GII e Tritone (ΔE= 2,87), cor 62 Biolux OMC e Natus Dent (ΔE=1,33), cor 67 Natus Dent e Tritone (ΔE=2,06) e Tritone e Vipi Dent Plus (ΔE=1,92). Concluiu-se que os resultados demonstraram poucas correlações entre as marcas avaliadas e as correlações existentes não ocorreram de forma igual para todas as cores, dificultando o sucesso dos tratamentos protéticos, assim como a comunicação entre o cirurgião dentista e o técnico em prótese dentária...


The objective of this study was to evaluate the correlation between colors of artificial acrylic resin teeth from different brands with the same name and identification. Five brands were selected: Vipi Dent Plus (VIPI), Biolux WTO (VIPI), Biocler G II (Dentbrás), Natus Dent (Dentbrás), and Tritone (VIPI), all using the same naming pattern. The used colors from each brand were: 60, 62, 65, 66, 67, and 69. To perform comparisons of color the Vita Easy Shade spectrophotometer was used. After three measurements of each color a mean was obtained All readings were performed on the central area of the tooth, at the same time and with clear standard gray background, obtaining the values of L*, a*, and b*. These values were tabulated for ΔE calculations, where ΔE < or = 3 represented significant and noticeable color difference. There is a correlation between the trademarks in color 60 Biocler GII and Natus Dent (ΔE = 3); Biocler GII and Tritone (ΔE = 2.87), color 62 Biolux WTO and Natus Dent (ΔE = 1.33), color 67 Natus Dent and Tritone (ΔE = 2.06), and Tritone and Vipi Dent Plus (ΔE = 1, 92). It was concluded that the results showed little correlation between the evaluated brands and correlation did not occur equally to all colors, hindering the success of prosthetic treatments as well as communication between the dental surgeon and dental technician...


Subject(s)
Humans , Spectrophotometers/methods , Dental Prosthesis , Composite Resins/chemistry , Tooth, Artificial , Color
4.
Rev. bras. ortop ; 50(2): 131-135, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-748349

ABSTRACT

The aim of this study was to review all cases of pseudoaneurysm in the literature, in predominantly arthroscopic procedures on the knee, and to report on a case of pseudoaneurysm that we treated. A bibliographic search was conducted for scientific articles published in Brazilian and foreign periodicals over the last 23 years. Forty-seven cases were found, in 40 articles. In addition to these 47 cases, there was the case that we treated, which was also included in the data. Among the operations that progressed with formation of a pseudoaneurysm, 60% were cases of meniscal injuries and 23%, anterior cruciate ligament injuries. In 46% of the cases, the artery affected with the popliteal, and in 21%, the inferomedial genicular artery. The commonest clinical symptom was pain (37%), followed by pulsating tumor (31%), edema of the calf (12%) and hemarthrosis (11%). The median time taken to make the diagnosis was 11 days, but it ranged from one day to 10 weeks after the procedure. Although rare, pseudoaneurysms are a risk that is inherent to arthroscopic surgery. All patients should be made aware of the vascular risks, even in small-scale procedures.


O objetivo deste estudo é revisar na literatura todos os casos de pseudoaneurisma em procedimentos predominantemente artroscópicos do joelho e relatar um caso de pseudoaneurisma tratado pelos autores. Foi feita uma pesquisa bibliográfica por meio de artigos científicos publicados em periódicos nacionais e internacionais nos últimos 23 anos. Foram levantados 47 casos, em 40 artigos. Somou-se aos 47 um caso dos autores deste estudo que foi incluído nos dados. Das cirurgias que cursaram com pseudoaneurisma, 60% se tratavam de lesões meniscais e 23% de lesões do ligamento cruzado anterior. Em 46% dos casos a artéria acometida foi poplítea e em 21% a artéria genicular inferomedial. O sintoma clínico mais comum foi dor (37%), seguido de tumor pulsátil (31%), edema de panturrilha (12%) e hemartrose (11%). A mediana do tempo para diagnóstico foi de 11 dias, mas variou de um dia até 10 semanas após o procedimento. Apesar de raro, o pseudoaneurisma é um risco inerente à cirurgia artroscópica. Todo paciente deve ser notificado dos riscos vasculares, mesmo em procedimentos de pequeno porte.


O objetivo deste estudo é revisar na literatura todos os casos de pseudoaneurisma em procedimentos predominantemente artroscópicos do joelho e relatar um caso de pseudoaneurisma tratado pelos autores. Foi feita uma pesquisa bibliográfica por meio de artigos científicos publicados em periódicos nacionais e internacionais nos últimos 23 anos. Foram levantados 47 casos, em 40 artigos. Somou-se aos 47 um caso dos autores deste estudo que foi incluído nos dados. Das cirurgias que cursaram com pseudoaneurisma, 60% se tratavam de lesões meniscais e 23% de lesões do ligamento cruzado anterior. Em 46% dos casos a artéria acometida foi poplítea e em 21% a artéria genicular inferomedial. O sintoma clínico mais comum foi dor (37%), seguido de tumor pulsátil (31%), edema de panturrilha (12%) e hemartrose (11%). A mediana do tempo para diagnóstico foi de 11 dias, mas variou de um dia até 10 semanas após o procedimento. Apesar de raro, o pseudoaneurisma é um risco inerente à cirurgia artroscópica. Todo paciente deve ser notificado dos riscos vasculares, mesmo em procedimentos de pequeno porte.


Subject(s)
Humans , Male , Young Adult , Aneurysm, False , Anterior Cruciate Ligament , Arteries , Arthroscopy , Knee
5.
Rev. bras. ortop ; 48(5): 417-420, Sept-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-697312

ABSTRACT

OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT), tibial plateau (TP) and tibial tuberosity (TT). A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the medial border of the patellar tendon and tibial tuberosity to the insertion of the flexor tendons of the knee. The angle between tibial plateau and the insertion of the flexor tendons of the knee (A-TP-FT) was calculated using Image Pro Plus software. RESULTS: The mean distance TP-FT was 41 ± 4.6 mm. The distance between the TT-FT was 6.88 ± 1 mm. The (A-TP-FT) was 20.3 ± 4.9°. CONCLUSION: In the anterior tibial flexor tendons are about 40 mm from the plateau with an average of 20°. .


OBJETIVO: Determinar parâmetros anatômicos para localizar a inserção dos tendões flexores do joelho na tíbia. MÉTODOS: Foram selecionados 10 joelhos de cadáveres com estruturas mediais e anteriores íntegras. A dissecção foi feita por acesso ânteromedial até a exposição adequada da inserção dos tendões flexores (TF), do planalto tibial (PT) e da tuberosidade anterior da tíbia (TAT). Uma agulha 40×12 e um paquímetro digital foram usados para aferir a distância do planalto tibial da inserção dos tendões flexores do joelho a 15 mm da borda medial ao tendão patelar e da tuberosidade anterior da tíbia à inserção dos tendões flexores do joelho. O ângulo o planalto tibial e a inserção dos tendões flexores do joelho (PT-TF) foi calculado com o auxílio do software ImagePro Plus(r). RESULTADOS: A distância PT-TF foi de 41 ± 4,6 mm em média. A distância entre a TAT-TF foi de 6,88 ± 1 mm. A angulação (PT-TF) foi de 20,3 ± 4,9 graus. CONCLUSÃO: Na região anterior da tíbia os tendões flexores estão a cerca de 40 mm do planalto com um ângulo médio de 20 graus. .


Subject(s)
Humans , Anatomy , Cadaver , Knee/anatomy & histology
6.
Rev. bras. ortop ; 48(5): 402-405, Sept-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-697320

ABSTRACT

OBJECTIVE: To study the anatomy of the oblique popliteal ligament, as regards its dimensions, expansion and anatomical relationships. METHODS: Eleven cadaver knees were dissected in order to study the anatomy and take mea-surements of anatomical structures and relationships of the oblique popliteal ligament. The dissection was for posterior access to the proper exposure of the oblique popliteal ligament, the semimembranosus muscle and its expansions. For measurement of dimensions, 40 × 12 needles were used for marking the specific points and a caliper. The angles were calculated using the software ImagePro Plus(r) . RESULTS: The distance from the origin of the oblique popliteal ligament to the tibial plateau was 7.4 mm, the thickness at its origin was 7.3 mm, length was 33.6 mm and the tibial plateau angle 34.8°. The length of the expansion of the proximal oblique popliteal ligament was 39.2 mm, thickness 7.8 mm and angle of the oblique popliteal ligament with its expansion 32.2°. CONCLUSION: The oblique popliteal ligament is thick, rises in the semimembranosus and protrudes proximally forming an acute angle with the joint interline, crossing the popliteal fossa. In some cases it has a proximal expansion. .


OBJETIVO: Estudar a anatomia do ligamento poplíteo oblíquo no que se refere às suas dimensões, expansões e relações anatômicas. MÉTODOS: Onze joelhos de cadáveres foram dissecados com o intuito de se estudar a anatomia e fazer medições das estruturas e das relações anatômicas do ligamento poplíteo oblíquo. A dissecção foi por acesso posterior até a exposição adequada do ligamento poplíteo oblíquo, do músculo semimembranoso e de suas expansões. Para aferição das medidas, foram usados agulhas 40x12 na marcação dos pontos específicos e um paquímetro. Os ângulos foram calculados com o auxílio do software ImagePro Plus(r). RESULTADOS: A distância da origem do ligamento poplíteo oblíquo ao platô tibial foi de 7,4 mm, a espessura na sua origem foi de 7,3 mm, o comprimento foi de 33,6 mm e o ângulo com o platô tibial foi de 34,8°. O comprimento da expansão proximal do ligamento poplíteo oblíquo foi de 39,2 mm, a espessura foi de 7,8 mm e o ângulo do ligamento poplíteo oblíquo com sua expansão foi de 32,2°. CONCLUSÃO: O ligamento poplíteo oblíquo é espesso, nasce no músculo semimembranoso, projeta-se proximalmente, forma um ângulo agudo com a interlinha articular e cruza a fossa poplítea. Em alguns casos apresenta uma expansão proximal. .


Subject(s)
Anatomy , Cadaver , Knee
7.
Arch. oral res. (Impr.) ; 8(3): 205-209, set.-dez. 2012. tab
Article in Portuguese | LILACS, BBO | ID: lil-706349

ABSTRACT

Introdução: A higiene das próteses totais é importante na prevenção de doenças cardíacas e pulmonares em pacientes idosos. Objetivo: Comparar a eficácia dos métodos de higienização para próteses totais. Materiais e métodos: Foram selecionados 20 pacientes portadores de próteses totais superiores. As próteses foram coradas com fucsina básica e, posteriormente, divididas em dois grupos de acordo com as soluções de higiene: grupo 1 – Corega Tabs® (CT); grupo 2 – hipoclorito de sódio (HS) 2,5%. No grupo 1, as próteses foram submersas em 250 mL de água destilada + 1 pastilha de Corega Tabs, no Grupo 2, em 250 mL de água destilada + 10 mL de hipoclorito de sódio a 2,5% por 5 minutos. Após a imersão, foi escovada a porção interna das próteses por um minuto. As bases internas das próteses foram coradas e fotografadas. Em seguida, realizaram-se imersão e imersão + escovação, e então, foi avaliada a quantidade de placa bacteriana pelo método da contagem de pontos. Os dados foram analisados pelos testes t de Student, ANOVA e múltiplas comparações de Tukey HSD. Resultados: Foram encontradas diferenças significativas entre a quantidade de placa bacteriana inicial e após imersão + escovação para ambos os grupos (CT, 40,12 ± 22,44 e 10,92 ± 11,39; HS, 40,64 ± 24,12 e 13,06 ± 11,08; p < 0,05). Não foram encontradas diferenças entre os grupos 1 e 2 para nenhuma condição teste (inicial, imersão e imersão + escovação) (p > 0,05). Conclusão: CT e HS não apresentaram diferenças para eficiência na remoção de placa bacteriana. O método de imersão + escovação mostrou-se o mais eficaz na remoção de placa bacteriana em próteses totais superiores.


Introduction: The hygiene of the dentures is important in the prevention of heart and lung disease in old patients. Objective: To compare the effectiveness of methods for cleaning dentures in reducing plaque. Materials and methods: We selected 20 patients with maxillary dentures. The prostheses were stained with basic fucsin Replak (Dentsply) and then divided into two groups according to the hygiene solutions: group 1 – Corega Tabs® (CT), group 2 - 2.5% sodium hypochlorite (HS). In group 1, the dentures were submerged in 250 mL of water + Corega Tabs; and group 2 in 250 mL of water + 10 mL of sodium hypochlorite 2.5% for five minutes. After soaking was done, the inner portion of the prosthesis was brushed for one minute. The foundations of internal prostheses were stained and photographed. After the initial period, immersion and immersion + brushing, and then evaluated the amount of plaque by the method of scoring. Data were analyzed by Student´s t-tests, ANOVA and Turkey HSD multiple comparisons. Results: Significant differences were found between the amount of initial plaque and immersion + brushing for both groups (CT, 40.12 ± 22.44 and 10.92 ± 11.39; HS, 40.64 ± 24.12 and 13.06 ± 11.08, p < 0.05). No differences were found between groups 1 and 2 test for any condition (initial, immersion and immersion + brushing) (p > 0.05). Conclusion: CT and HS showed no differences related to the efficiency in removing plaque. The immersion + brushing method proved to be the most efficient at removing plaque from maxillary denture.


Subject(s)
Humans , Biofilms , Denture, Complete, Upper , Denture Cleansers/pharmacology , Analysis of Variance , Disinfectants/pharmacology , Sodium Hypochlorite/pharmacology , Immersion , Materials Testing , Time Factors
8.
Full dent. sci ; 3(9): 70-75, out.-dez. 2011.
Article in Portuguese | LILACS, BBO | ID: lil-642909

ABSTRACT

Recentemente tem sido recomendada a utilizaçãode pinos de fibras de vidro em dentes tratadosendodonticamente devido às propriedades mecânicasserem semelhantes às da dentina. Váriassão as marcas comerciais de pinos, formatos emateriais de composição, porém a maior complexidadeestá na identificação da necessidade, ounão, de núcleo de preenchimento, assim como naescolha do material de retenção. A obtenção deuma boa adesão intrarradicular é de fundamentalimportância para a fixação dos pinos de fibra devidro e para proporcionar um bom selamento radicular,evitando a possibilidade de microinfiltração.Aspectos importantes a serem consideradossão: a anatomia intrarradicular, a fricção/adaptaçãodo pino no interior do canal radicular e a dificuldadede acesso nas regiões mais profundas doconduto, controle de umidade e fator-C. Esta revisãode literatura teve como objetivo apresentaras propriedades biomecânicas dos pinos de fibrasde vidro e os aspectos importantes da retençãono canal radicular.


Recently the use of fibreglass posts has beenrecommended for endodontically treatedteeth owing to their mechanical propertiesbeing similar to those of dentine. Severalcommercial brands of posts are available witha variety of shapes and composite materials,however the most complex task lies in identifyingwhether or not a core is necessary, andalso in choosing the retaining material. Theattainment of good intraradicular adhesionis of fundamental importance for fibreglasspost fixation and for providing good rootsealing in order to prevent the possibility ofmicro-infiltration. Important aspects to beconsidered are intraradicular anatomy, friction/adaptation of the posts inside the rootcanal and difficulty in accessing its deepestregions, humidity control and C-factors. Theaim of this revision of the literature was topresent the biomechanical properties of fibreglassposts and the important aspects ofretention in the root canal.


Subject(s)
Dental Cements , Dental Pulp Cavity , Post and Core Technique , Dental Pins
9.
RSBO (Impr.) ; 8(2): 189-193, jun. 2011. ilus, tab
Article in English | LILACS | ID: lil-591751

ABSTRACT

INTRODUCTION AND OBJECTIVE: The aim of this investigation was to evaluate through Finite Element Analysis (FEA) the displacement and stress distribution of prefabricated serrated and tapered dental root posts of different compositions: carbon fiber, glass fiber and titanium. MATERIALS AND METHODS: Through this biomechanical analysis a carbon fiber post (CF), a glass fiber post (GF) and a titanium post (TI) were compared according to their design (tapered [T]) and serrated [S]) and under a load of 250 N, at 45º, in order to simulate an occlusal load of a canine tooth. RESULTS: FEA demonstrated the following maximum displacement (MXD) in millimeters: T.CF (tapered carbon fiber post) = 2.48 mm; T.GF = 1.58 mm; T.TI = 0.50 mm; S.CF = 7.66 mm; S.GF = 4.87mm. CONCLUSION: These results showed that the carbon fiber post demonstrated the greatest displacement, followed by the glass fiber and the titanium posts. The tapered design presented detachment values much lower than the serrated design.

10.
J. Health Sci. Inst ; 27(1)jan.-mar. 2009. ilus
Article in Portuguese | LILACS | ID: lil-545273

ABSTRACT

O objetivo desse estudo foi demonstrar a técnica de utilização de pinos intrarradiculares em fibras de vidro translúcido. Foi selecionado um elemento dentário (incisivo lateral superior) de uma paciente do gênero feminino, 36 anos de idade atendida na disciplina de Dentística Restauradora da Universidade Estadual de Ponta Grossa (UEPG). O elemento dentário foi tratado endodonticamente e possuía restauração provisória deficiente. Esse procedimento foi realizado com o intuito de gerar retenção ao material restaurador definitivo e reforçar a porção coronária remanescente do elemento dentário, minimizando, assim, a probabilidade de fratura. A utilização do pino intrarradicular em fibras de vidro contribui para a manutenção da estética do elemento dentário, além de promover uma melhor distribuição das tensões nas estruturas dentárias e a retenção do material restaurador. Pinos em fibras de vidro contribuem para a estética natural dos elementos dentários.


The aim of this study was to demonstrate the technique of use of translucent glass fiber root posts. It was selected a teeth (maxilar lateral incisor) of a female patient, 36 years old assisted in the discipline of Dentistry of the State University of Ponta Grossa (UEPG). The dental element sufferred endodontics treatment and it has deficient temporary restoration. That procedure was accomplished with the intention of to generate retention to the definitive restoring material and to reinforce the remaining coronary portion of the dental element, minimizing, like this, the fracture probability. The use of the glass fiber root posts contributed to the maintenance of the aesthetics of the dental element, besides promoting a better distribution of the tensions in the dental structures and the retention of the restoring material. Glass fiber posts contribute to the natural aesthetics of the dental element.


Subject(s)
Humans , Female , Adult , Esthetics, Dental , Post and Core Technique , Dental Pins , Tooth Preparation/methods , Tooth Preparation
11.
RGO (Porto Alegre) ; 56(4): 429-436, out.-dez. 2008.
Article in Portuguese | LILACS, BBO | ID: lil-502116

ABSTRACT

Novos materiais restauradores têm sido desenvolvidos para cumprir não apenas as exigências funcionais, mas também estéticas. Nos últimos anos, uma gama enorme destes novos materiais tem surgido no mercado odontológico, entre eles, diversos sistemas adesivos e diferentes técnicas operatórias para cada um deles. Portanto, torna-se imprescindível que o profissional tenha conhecimento das propriedades, características, bem como da associação desses materiais com as estruturas dentárias, para selecioná-los e utilizá-los de forma correta. Deve-se utilizar os sistemas adesivos convencionais ou os autocondicionantes? Esse questionamento incentivou a realização desta revisão de literatura, visando comparar os sistemas adesivos convencionais com os autocondicionantes e buscar dados científicos que auxiliem na escolha do sistema adesivo. Os sistemas adesivos autocondicionantes, quando comparados aos convencionais, demonstram uma menor sensibilidade técnica, especialmente em relação aos erros que o operador possa cometer. Os sistemas adesivos autocondicionantes, especialmente os de dois passos, têm mostrado valores equivalentes de resistência adesiva, infiltração marginal e desempenho; portanto, passam a ser uma opção em restaurações adesivas diretas em dentes posteriores.


New dental restorative materials have been developed to meet not only the functional demands, but esthetics as well, and in the last few years an enormous range of new materials has appeared for use in dentistry. Among them, several adhesive systems, and different operative techniques for each group materials. Therefore, is indispensable for the professional to know about the properties, characteristics, and association of these materials with the dental structures, in order to select and use them correctly. Should conventional self-etching adhesive systems be used? This question encouraged this literature review to be conducted, with the aim of comparing the conventional adhesive systems with the self-etching systems and to look for scientific data that would help professionals to choose which adhesive system to use. When compared to conventional systems, it was noted that the self-etching systems show less sensitivity to technique, especially as regards errors the operator could commit. The self-etching systems, particularly the 2-step type, have shown equivalent values of bond strength, marginal microleakage and performance, therefore, will be an option for direct composite resin restorations in posterior teeth.


Subject(s)
Dentin-Bonding Agents , Composite Resins/therapeutic use , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL